Number plate lamp short-circuit

Discuss Electrical problems here.
Forum rules
By using this site, you agree to our rules. Please see: Terms of Use
Post Reply
winger300
Minor Fan
Posts: 358
Joined: Thu Apr 15, 2004 5:54 pm
Location: Stockport, Manchester
MMOC Member: No

Number plate lamp short-circuit

Post by winger300 »

Hi,

I had a problem with my number plate light shorting out and causing the wire to melt.

It seems that the bulb holder is shorting out on the boot-lid around the posts that bolt it on. There is nothing to isolate them from the earthed body. I've bodged a fix with some rubber glove squashed in there,

but what was originally used to isolate it? It can't be just the paint :o
PSL184
Minor Legend
Posts: 4978
Joined: Thu Jul 03, 2008 5:49 pm
Location: Nuneaton
MMOC Member: No

Re: Number plate lamp short-circuit

Post by PSL184 »

The problem is the insulation between the bulb holder and the base that has given up. The earth is through the base so if the bulb holder is no longer isolated it will short directly to earth....
[sig]8426[/sig]

Compare the Minors - Simples !! http://mog.myfreeforum.org/index.php
mike.perry
Series MM Registrar
Posts: 10183
Joined: Sun Jul 24, 2005 11:39 pm
Location: Reading
MMOC Member: No

Re: Number plate lamp short-circuit

Post by mike.perry »

Fit rubber gromets in the mounting holes to insulate the mounting bolts from the light base
[sig]3580[/sig]
bmcecosse
Minor Maniac
Posts: 46561
Joined: Wed Feb 16, 2005 11:24 pm
Location: ML9
MMOC Member: No

Re: Number plate lamp short-circuit

Post by bmcecosse »

Fix the insulation - or buy a new light!
ImageImage
Image
winger300
Minor Fan
Posts: 358
Joined: Thu Apr 15, 2004 5:54 pm
Location: Stockport, Manchester
MMOC Member: No

Re: Number plate lamp short-circuit

Post by winger300 »

Ah, I think my problem is that the thing is wired incorrectly. The base should be earth, and the inner contacts live?
PSL184
Minor Legend
Posts: 4978
Joined: Thu Jul 03, 2008 5:49 pm
Location: Nuneaton
MMOC Member: No

Re: Number plate lamp short-circuit

Post by PSL184 »

winger300 wrote:Ah, I think my problem is that the thing is wired incorrectly. The base should be earth, and the inner contacts live?
Correct :o :lol:
[sig]8426[/sig]

Compare the Minors - Simples !! http://mog.myfreeforum.org/index.php
paulk
Minor Legend
Posts: 1239
Joined: Mon Feb 07, 2005 4:49 pm
Location: Itchen, Southampton
MMOC Member: No

Re: Number plate lamp short-circuit

Post by paulk »

Did that myself once.

Wondered why I could smell cooking wire after a late night rebuilding of a boot lid.

S'easy done but also easy to fix. Just make sure you haven't melted the insulation off the wire by checking all the way back to the dashboard.
Paulk


[img]http://i23.photobucket.com/albums/b359/paulk235/DSCF0807.jpg[/img]
1959 2dr Milly
Has now sat in back garden for 5 years :(
http://www.sadmog.morrisminor.com/
Post Reply